Reliable Isolation Under All Conditions

The 16.8 Large HV Pendulum Isolation Valve provides reliable isolation performance also under harsh process conditions. It is ideal for isolation requirements in applications with large volume flows such as large coating or display production systems. Therefore, it is offered in DN 400 and 500mm. The 16.8 valve provides optional a 3-position pneumatic or a standard pneumatic, both double acting.
With its special split body design it allows maintenance without any disassembly of pipe connections or process chamber connections. Its slim design allows to mount the 16.8 directly to a process chamber, eliminating e.g. the volume normally required in a chamber - valve - pump connection.
With its robust design as well as a variety of design options, the 16.8 series is easy to integrate into various vacuum processes.
Already installed in hundreds of batch and inline production systems around the world under various process conditions, the 16.8 series has proven its outstanding performance in all aspects.


VAT
Pneumatic
VAT
3-position pneumatic

/
16.8 in closed position

The 16.8 Large HV Pendulum Isolation Valve is available in aluminum with standard flange connectors in ISO-F and JIS. Customer-specific flanges can be integrated. Further options are ports for roughing (by-pass), venting or for gauges. As the 16.8 is often used to isolate turbo pumps a splinter shield grid is also available.


Key features of the 16.8 Large HV Pendulum Isolation Valve

Features:

    • Reliable isolation for large vacuum volumes
    • Reliable performance also under harsh conditions
    • Quick and easy maintenance through slit body design

Benefits:

    • High uptime
    • Low cost of operation
    • Adjustable to process requirements
  • Technical data
Sizes DN 400 (16"), DN 457 (16"), DN 500 (20")
ActuatorsPneumaticDouble acting
 3-position-pneumaticDouble acting
Body material Aluminum
Feedthrough Rotary feedthrough
Standard flanges ISO-F, ASA, JIS
Leak rateValve body, valve seat< 1 × 10-9 mbar ls-1
Pressure range 1 × 10-8 mbar to 1.2 bar (abs)
Differential pressure on the plate ≤ 1.2 bar
Differential pressure at opening ≤ 30 mbar
Cycles until first service 100 000
TemperatureValve body
Actuator
Solenoid valve
Position indicator
≤ 120 °C
≤ 80 °C
≤ 50 °C
≤ 80 °C
Heating and cooling rate ≤ 30 °C h-1
MaterialValve body
Plate
Feedthrough (parts in contact with media)
EN AC-421000 (3.2371)
EN AW-6082 (3.2315)
EN AW-6082 (3.2315), AISI 303 (1.4305)
SealBonnet, plate, feedthroughFKM (Viton®)
Mounting position Any
Solenoid valve 24 V DC, 5.4 W (others on request)
Position indicator: contact ratingVoltage
Current
≤ 50 V AC/DC
≤ 3 A
Valve position indication Visual (mechanical)

 